深圳市奥德赛创精密仪器有限公司

深圳市奥德赛创精密仪器有限公司 收藏

主营产品:防火阻燃试验机、防水等级试验装置、电子万能试验机、标准试验指销棒

当前位置 : 
首页>
供应产品>
供应IEC60695-2-2针焰测试仪 德国WAZAU***针焰测试仪
扫一扫
添加商家微信
公司信息
产品分类
联系方式
  • 联系人:
    常先生
  • 职 位 :
    业务经理
  • 电 话 :
    𐁑𐁓𐁕𐁕𐁖𐁒𐁗𐁕𐁗𐁘𐁘𐁕𐁐
  • 手 机 :
    𐁏𐁐𐁑𐁒𐁐𐁓𐁔𐁐𐁕𐁔𐁑
  • 地 址 :
    广东 深圳 宝安区 广东省深圳市宝安区松岗沙江路162号佳裕产业园1栋9楼
  • 客 服 :
    点击这里给我发消息
供应IEC60695-2-2针焰测试仪 德国WAZAU***针焰测试仪
订货量(台) 价格
1 - 1 88.00元/
2 - 2 85.00元/
≥3 83.00元/
  • 发 货 期:3天内发货
  • 所 在 地:广东 深圳
  • 手     机: 𐁏𐁐𐁑𐁒𐁐𐁓𐁔𐁐𐁕𐁔𐁑

详细信息

是否进口: 产地: /
加工定制: 品牌: 德国WAZAU
型号: NPG 产品适用范围: 着火危险性的测定
测量范围: / 电源: /
工作电压: /V 外形尺寸: /
重量: /kg    

IEC60695-2-2针焰测试仪   德国WAZAU***针焰测试仪


应用领域:主要用于模拟技术评定设备内部由于某种故障条件所造成的小火焰的着火危险性试验的专业仪器。适用于电子电工的设备及其部件和元件的着火危险性的测定,也适用于固体电气绝缘材料或其它可燃材料的着火危险性。

Needle Flame Tester in accordance with DIN EN 60695-2-2 

 

ModelNPG

 

The tester serves to test with a needle flame, to simulate the impact of small flames, that might occur by faulty working conditions of the product, to evaluate the risk of fire by means of a imitating test procedure. The test flame is the source of fire impacting on the sample for a certain period of time. The confirmation of the flame is conducted by the flame test arrangement and the calibration device. The temperature on the copper block is determined using a sheathed thermocouple type K (class 1) in accordance with IEC  60584-2. The calibration device is able to monitor the space of time from 100℃ to 700℃ and calculate the average time from three time measurements. The calibration device provides a digital and an analogical temperature output the time can be determined externally from. 

 

Set-Up 

Connect the calibration device to your power supply and the thermocouple on the back side of the calibration device. Connect the needle flame burner to the gas supply. The needle flame burner needs to be operated at 50 mbar. Connect the thermocouple to calibration device at the back side of the housing (picture 1). 

 

Conducting the Flame Confirmation 

Mount the thermocouple with its support to the stand. Adjust carefully on the height adjustment of the stand the distance in between copper block and burner pipe to 6 mm (picture 3). To do that the burner has to be in a vertical position. Fix its position so that the needle flame burner is below the copper block by adjusting the stop on the guiding rod. That way the position for the calibration procedure is fixed. After that move the needle flame burner to its initial position to the right side of the tester. Ignite the burner and turn on the calibration device. The flame height template has to be mounted (picture 6) so that the lower edge of the template’s sinking is on the same level as the shoulder of the needle flame  burner (diameter 6  mm).Set  the  height  of  flame  according  to  the  standard  and  height 

adjustment template (picture 2). The gas flow to the needle flame burner can be adjusted by the fine adjustment valve on the front side of the tester (picture 4). When the calibration device is in working condition move the needle flame burner carefully below the copper block and heat it up (picture 5). Then the burner must not be moved anymore or the flame disturbed by ambient air flows. After the temperature has risen up to 700℃ the measurement is completed and the burner can be put in its initial position. Before running a new test let the copper block cool down below 50℃ without any external help. 


我公司长期提供【供应IEC60695-2-2针焰测试仪 德国WAZAU***针焰测试仪】,如果您对我们的【供应IEC60695-2-2针焰测试仪 德国WAZAU***针焰测试仪】感兴趣,请随时拨打下方的电话,点击留言或QQ与我交谈。联系我时,请说明是在供应商网上看到的,谢谢!

联系人 常先生
电话 0755-26563358